Furnaces
Ashing Furnaces with Flap Door or Lift Door
The ashing furnaces LV 3/11 - LVT 15/11 are especially designed for ashing in the laboratory. A special air intake and exhaust system allows air exchange of more than 6 times per minute. Incoming air is preheated to ensure a good temperature uniformity.
- Tmax 1100 °C
- Heating from two sides
- Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
- Air exchange of more than 6 times per minute
- Good temperature uniformity due to preheating of incoming air
- Insulation made of non-classified fiber material
- Housing made of sheets of textured stainless steel
- Dual shell housing for low external temperatures and stability
-Optional flap door (LV) which can be used as work platform or lift door (LVT) with hot surface facing away from the operator
- Solid state relays provide for lownoise operation
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment :
- Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
- Process control and documentation via VCD software package for monitoring, documentation and control
|
Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions in mm |
Connected |
Electrical |
Weight |
Minutes |
||||
|
Flap door |
°C |
w |
d |
h |
in l |
W |
D |
H1 |
load kW |
connection* |
in kg |
to Tmax2 |
|
LV 3/11 |
1100 |
160 |
140 |
100 |
3 |
385 |
360 |
735 |
1.2 |
1-phase |
20 |
120 |
|
LV 5/11 |
1100 |
200 |
170 |
130 |
5 |
385 |
420 |
790 |
2.4 |
1-phase |
35 |
120 |
|
LV 9/11 |
1100 |
230 |
240 |
170 |
9 |
415 |
485 |
845 |
3.0 |
1-phase |
45 |
120 |
|
LV 15/11 |
1100 |
230 |
340 |
170 |
15 |
415 |
585 |
845 |
3.5 |
1-phase |
55 |
120 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions in mm |
Connected |
Electrical |
Weight |
Minutes |
||||
|
Lift door |
°C |
w |
d |
h |
in l |
W |
D |
H1 |
load kW |
connection* |
in kg |
to Tmax2 |
|
LVT 3/11 |
1100 |
160 |
140 |
100 |
3 |
385 |
360 |
735 |
1.2 |
1-phase |
20 |
120 |
|
LVT 5/11 |
1100 |
200 |
170 |
130 |
5 |
385 |
420 |
790 |
2.4 |
1-phase |
35 |
120 |
|
LVT 9/11 |
1100 |
230 |
240 |
170 |
9 |
415 |
485 |
845 |
3.0 |
1-phase |
45 |
120 |
|
LVT15/11 |
1100 |
230 |
340 |
170 |
15 |
415 |
585 |
845 |
3.5 |
1-phase |
55 |
120 |
|
1Including exhaust tube (Ø 80 mm) *Please see page 60 for more information about supply voltage |
||||||||||||