PRODUCT |  HI263X

  •  Product name : HI263X
  •  Category : Water Analysis Equipment » Hanna Instruments
  •  Catalog : HI263X_support.pdf

Description

HI263X

EC/TDS Simple Benchtop Meter

 

Seamless design. Exceptional performance. Quality measurements. These Benchtop Meters prove that simplicity is best, combining functionality with precision. Built for regular, everyday testing, our Benchtop Meters are easy to incorporate into your lab routine.

 

  • Accurate and dependable. Collect consistent EC and TDS results
  • Fast and repeatable. Pair with supplied Digital Smart Conductivity Electrode for stable, noise-free readings
  • Convenient and user-friendly. Testing is effortless with large, readable screens and clear navigation menus

 

The right choice for any environment, our Simple Benchtop Meters are ideal for laboratories, colleges and universities, small to medium-sized manufacturing plants, wineries, and more.

There are two options available to choose from:

Option 1: Our EC/TDS Benchtop Meter (HI2630) with basic functionality, one operation mode, and no data logging capabilities

Option 2: Our EC/TDS Benchtop Meter (HI2631) with two operation modes (standard and basic) and the ability to log, store, and transfer GLP data

 

Specification

 

HI2630 and HI2631

using the four-ring conductivity probe

EC Range

0.00 to 29.99 μS/cm
30.0 to 299.9 μS/cm
300 to 2999 μS/cm
3.00 to 29.99 mS/cm
30.0 to 200.0 mS/cm
up to 500.0 mS/cm absolute conductivity ‡

EC Resolution

0.01 μS/cm
0.1 μS/cm 1 μS/cm
0.01 mS/cm 0.1 mS/cm

EC Accuracy at 25 °C / 77 °F

±1% of reading
(±0.05 μS/cm or 1 digit,whichever is greater)

TDS Range

0.00 to 14.99 ppm (mg/L)
15.0 to 149.9 ppm (mg/L)150 to 1499 ppm (mg/L)
1.50 to 14.99 g/L
15.0 to 100.0 g/L
up to 400.0 g/L (with 0.80 factor) absoluteTDS***

TDS Resolution

0.01 ppm
0.1 ppm
1 ppm 0.01 g/L

TDS Accuracy at 25 °C / 77 °F

±1% of reading (±0.03 ppm or 1 digit, whichever is greater

Salinity* Range

0.0 to 400.0 % NaCl
2.00 to 42.00 PSU
0.00 to 80.00 g/L

Salinity* Resolution

0.1% NaCl
0.01 PSU
0.01 g/L

Salinity* Accuracy at 25 °C / 77 °F

±1% of reading

Temperature Range

−20.0 to 120.0 °C**(−4.0 to 248.0 °F)

Temperature Resolution

0.1 °C (0.1 °F)

Temperature Accuracy at 25 °C / 77 °F

±0.5 °C (0.9 °F)

EC calibration

"Cell factor calibration
Six standards available: 84 µS/cm, 1413 μS/cm 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm
One point offset: 0.00 μS/cm"

Salinity calibration* (% NaCl only)

Single point with HI7037 standard

Temperature compensation

• Automatic, −5 to 100 °C (23 to 212 °F)
• NoTC, can be selected to measure absolute conductivity

Conductivity temperature coefficient*

0.00 to 6.00 %/°C (EC and TDS only)
(1.90 %/°C default)

TDS factor*

0.40 to 0.80 (0.50 default)

DO Salinity compensation

0 to 40 g/L

Logging (HI2631 only)

Up to 1000* (400) records organized in:
• Manual log-on-demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging, maximum 600 logs (100 lots)*

Notes

*When operating in Standard Mode in HI2631 only!br>** Temperature limits will be reduced to actual probe limits.
*** Absolute conductivity (TDS) is the conductivity value without temperature compensation.

PC interface (HI2631 only)

USB-C

Power supply

USB Type C (5 VDC; 500 mA)

Environment

0 to 50 °C (32 to 122 °F)
Maximum 95 % RH non-condensing

Dimensions

205 x 160 x 77 mm (8.0 x 6.2 x 3.0 inches)

Weight

Approximately 0.85 kg (1.87 lbs.)

 

Our Principal

alp
Brookfield Ametek
Innotech
kern
rion
rocker
velp
thermo
ika
hanil
Extech
Ritter
Haver & Boecker
Shaw
Nabertherm
Hildebrand
Ludwig
Atago